Flame Series

Flame Plasma Treatment for Objects

Powerful Flame Treatment
with Precise Control

Improve adhesion on plastics, glass,
metals and more.

Enercon Flame Plasma Treaters offer safe and reliable surface treatment for any flat or dimensional surface. Our advanced combustion control architecture and unique high velocity power burner ensures powerful and repeatable surface treating results.

  • IMPROVES ADHESION OF INKS,
    COATINGS & ADHESIVES
  • LONG LASTING, UNIFORM, HIGH
    TREATMENT LEVELS
  • FAIL SAFE DESIGN
  • ADVANCED CONTROL
    ENSURES RELIABILITY
  • EFFICIENT SURFACE
    DECONTAMINATION AND
    POLISHING
Plastics, Metals & Glass - Flame Plasma Technology Application

PowerFlame™ High Velocity Burner Technology

PowerFlame™ High Velocity Burner
  • High-velocity ports for powerful treatment
  • Multiple burner designs for optimal dwell time
  • Uniform treatment across entire width of burner
  • Eliminates laning or striations
  • Brass inserts are easily removed for cleaning
  • Variable treat widths utilizing burner deckling
Flame Plasma Treating Systems

Advanced Combustion Control

  • Air/gas ratio control provides a consistent flame over the entire power adjustment range
  • Flow meters for air & gas provide precise reproduction of process parameters
  • Adjust flame power with a single control
  • Operate on natural gas or propane
 

PRO SYSTEM FEATURES ALSO INCLUDE

  • Intuitive Touch Screen Display guides users through operation, monitoring, fault logs & more
  • Closed loop flow control technology
  • Eliminates manual adjustments and calibration
  • Advanced Troubleshooting, Software Updates & Data Access through USB port
  • Remote start/stop & prime capabilities through Enercon supplied cables or advanced communication through ethernet

Flame Plasma Safety

  • FAIL SAFE DESIGN

    Stops gas flow if any critical device in the cabinet fails

  • SAFETY SOLENOID VALVES

    Redundant valves in the gas train immediately prevent gas flow if any of the monitored variables are not satisfied.

  • PRESSURE SWITCHES

    Mounted to air and gas lines to detect adequate pressure

  • REVERSE FLOW VALVE

    Prevents backflow into the gas line

  • FLAME DETECTION ELECTRODE

    Works in conjunction with the flame safety relay to monitor the presence of the flame at the burner.

  • FLAME SAFETY RELAY

    Monitors flame & controls the redundant safety solenoid gas line valves