{"id":1836,"date":"2023-09-27T21:38:31","date_gmt":"2023-09-27T21:38:31","guid":{"rendered":"https:\/\/www.enerconind.com\/plasma-treating\/?post_type=resources&#038;p=1836"},"modified":"2026-03-23T20:15:59","modified_gmt":"2026-03-23T20:15:59","slug":"unique-and-custom-plasma-treating-designs-for-difficult-to-reach-surfaces","status":"publish","type":"resources","link":"https:\/\/www.enerconind.com\/plasma-treating\/library-resource\/unique-and-custom-plasma-treating-designs-for-difficult-to-reach-surfaces\/","title":{"rendered":"Unique and Custom Plasma Treating Designs for Difficult to Reach\u00a0Surfaces"},"content":{"rendered":"\n<p>Enercon\u2019s&nbsp;<a href=\"\/plasma-treating\/plasma-flame-treaters\/blown-ion-125\/\">Blown-ion\u2122 plasma discharge<\/a>&nbsp;heads are well known for their ability to improve surface adhesion with inks, adhesives and coatings. They can be integrated in with robotics, indexing systems and conveyor systems to provide precise treatment that cleans, etches, and functionalizes surfaces. And, they are very effective at reaching crevices and small areas.<\/p>\n\n\n\n<p>Until recently, this technology was limited for applications that had enough room for the treatment head and a straight direct path to the surface to be treated. Enercon has developed numerous new discharge head configurations that can enable plasma treatment for applications that were once not possible.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"760\" height=\"207\" src=\"https:\/\/media.enerconind.com\/wp-content\/uploads\/sites\/4\/2023\/09\/02144950\/blown-ion-custom-discharge-heads.jpg\" alt=\"\" class=\"wp-image-1837\" srcset=\"https:\/\/media.enerconind.com\/wp-content\/uploads\/sites\/4\/2023\/09\/02144950\/blown-ion-custom-discharge-heads.jpg 760w, https:\/\/media.enerconind.com\/wp-content\/uploads\/sites\/4\/2023\/09\/02144950\/blown-ion-custom-discharge-heads-300x82.jpg 300w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><\/figure>\n\n\n\n<p>Enercon\u2019s Business Development Director Wilson Lee says, \u201cBy modifying the components of the discharge head, we are now able to use Blown-ion\u2122 plasma to treat surfaces at angles that could not have been previously reached because of challenging geometries of the part and space available for the application were prohibitive. By modifying the discharge head, we are able to provide efficient and consistent treatment to improve adhesion.\u201d<\/p>\n\n\n\n<p>The new discharge heads enable plasma to reach under, around, and into recessed surface areas. Common applications include window and door manufacturing, siding, channels, deeply recessed areas, automotive, and&nbsp;more.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:45%\">\n<p>For applications requiring more treatment power in a single pass Enercon has developed a series of <a href=\"https:\/\/www.enerconind.com\/plasma-treating\/plasma-flame-treaters\/blown-ion-multiport\/\" type=\"page\" id=\"2311\">Blown-ion\u2122 plasma treaters with MultiPort\u2122 Technology.<\/a>  <\/p>\n\n\n\n<p>These powerful plasma treaters are available in multiple configurations for applications requiring high levels of treatment, providing robust and homogenous treatment to improve surface energy and adhesion.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"526\" src=\"https:\/\/media.enerconind.com\/wp-content\/uploads\/sites\/4\/2025\/07\/02201625\/BI250500discharge.jpg\" alt=\"Blown-ion 250 and 500 Plasma Discharge\" class=\"wp-image-2318\" style=\"aspect-ratio:1.4997462072077152;width:346px;height:auto\" srcset=\"https:\/\/media.enerconind.com\/wp-content\/uploads\/sites\/4\/2025\/07\/02201625\/BI250500discharge.jpg 800w, https:\/\/media.enerconind.com\/wp-content\/uploads\/sites\/4\/2025\/07\/02201625\/BI250500discharge-300x197.jpg 300w, https:\/\/media.enerconind.com\/wp-content\/uploads\/sites\/4\/2025\/07\/02201625\/BI250500discharge-768x505.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<p>Enercon maintains an inventory of these custom discharge heads for use in our surface treating laboratory. Free trials to determine the effectiveness of plasma can be scheduled by visiting the company\u2019s&nbsp;<a href=\"\/plasma-treating\/lab-trials\/\">surface treating laboratory web page<\/a>. It should be noted that if Enercon does not have a discharge head that will work for your application, we may be able to custom engineer a design that will work.<\/p>\n\n\n\n<p>For more information please&nbsp;<a href=\"https:\/\/www.enerconind.com\/plasma-treating\/contact-us.aspx\">cont<\/a><a href=\"\/plasma-treating\/contact-us\/\">act us<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Enercon\u2019s&nbsp;Blown-ion\u2122 plasma discharge&nbsp;heads are well known for their ability to improve surface adhesion with inks, adhesives and coatings. They can be integrated in with robotics, indexing systems and conveyor systems to provide precise treatment that cleans, etches, and functionalizes surfaces. And, they are very effective at reaching crevices and small areas. Until recently, this technology&hellip;<\/p>\n","protected":false},"featured_media":1838,"parent":0,"menu_order":170,"template":"","format":"standard","resource_type":[25],"technology":[39],"material":[],"application_subcategory":[51],"resource_application":[29,31,32,33,37,35],"class_list":["post-1836","resources","type-resources","status-publish","format-standard","has-post-thumbnail","hentry","resource_type-technical-article","technology-plasma","application_subcategory-technologies","resource_application-automotive","resource_application-consumer-goods","resource_application-electronics","resource_application-medical","resource_application-other","resource_application-windows-doors"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Unique and Custom Plasma Treating Designs for Difficult to Reach\u00a0Surfaces - Plasma Surface Treating<\/title>\n<meta name=\"description\" content=\"Learn about unique plasma surface treatment heads that are effective for hard to reach spaces.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.enerconind.com\/plasma-treating\/library-resource\/unique-and-custom-plasma-treating-designs-for-difficult-to-reach-surfaces\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Unique and Custom Plasma Treating Designs for Difficult to Reach\u00a0Surfaces - Plasma Surface Treating\" \/>\n<meta property=\"og:description\" content=\"Learn about unique plasma surface treatment heads that are effective for hard to reach spaces.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.enerconind.com\/plasma-treating\/library-resource\/unique-and-custom-plasma-treating-designs-for-difficult-to-reach-surfaces\/\" \/>\n<meta property=\"og:site_name\" content=\"Plasma Surface Treating\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-23T20:15:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/media.enerconind.com\/wp-content\/uploads\/sites\/4\/2023\/09\/02144950\/blown-ion-custom-vertical-and-quad-ports.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"384\" \/>\n\t<meta property=\"og:image:height\" content=\"266\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.enerconind.com\\\/plasma-treating\\\/library-resource\\\/unique-and-custom-plasma-treating-designs-for-difficult-to-reach-surfaces\\\/\",\"url\":\"https:\\\/\\\/www.enerconind.com\\\/plasma-treating\\\/library-resource\\\/unique-and-custom-plasma-treating-designs-for-difficult-to-reach-surfaces\\\/\",\"name\":\"Unique and Custom Plasma Treating Designs for Difficult to Reach\u00a0Surfaces - Plasma Surface Treating\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.enerconind.com\\\/plasma-treating\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.enerconind.com\\\/plasma-treating\\\/library-resource\\\/unique-and-custom-plasma-treating-designs-for-difficult-to-reach-surfaces\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.enerconind.com\\\/plasma-treating\\\/library-resource\\\/unique-and-custom-plasma-treating-designs-for-difficult-to-reach-surfaces\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/media.enerconind.com\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2023\\\/09\\\/02144950\\\/blown-ion-custom-vertical-and-quad-ports.jpg\",\"datePublished\":\"2023-09-27T21:38:31+00:00\",\"dateModified\":\"2026-03-23T20:15:59+00:00\",\"description\":\"Learn about unique plasma surface treatment heads that are effective for hard to reach spaces.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.enerconind.com\\\/plasma-treating\\\/library-resource\\\/unique-and-custom-plasma-treating-designs-for-difficult-to-reach-surfaces\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.enerconind.com\\\/plasma-treating\\\/library-resource\\\/unique-and-custom-plasma-treating-designs-for-difficult-to-reach-surfaces\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.enerconind.com\\\/plasma-treating\\\/library-resource\\\/unique-and-custom-plasma-treating-designs-for-difficult-to-reach-surfaces\\\/#primaryimage\",\"url\":\"https:\\\/\\\/media.enerconind.com\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2023\\\/09\\\/02144950\\\/blown-ion-custom-vertical-and-quad-ports.jpg\",\"contentUrl\":\"https:\\\/\\\/media.enerconind.com\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2023\\\/09\\\/02144950\\\/blown-ion-custom-vertical-and-quad-ports.jpg\",\"width\":384,\"height\":266,\"caption\":\"Custom plasma treating heads for hard-to-reach places.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.enerconind.com\\\/plasma-treating\\\/library-resource\\\/unique-and-custom-plasma-treating-designs-for-difficult-to-reach-surfaces\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.enerconind.com\\\/plasma-treating\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Technical Article\",\"item\":\"https:\\\/\\\/www.enerconind.com\\\/plasma-treating\\\/resource_type\\\/technical-article\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Unique and Custom Plasma Treating Designs for Difficult to Reach\u00a0Surfaces\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.enerconind.com\\\/plasma-treating\\\/#website\",\"url\":\"https:\\\/\\\/www.enerconind.com\\\/plasma-treating\\\/\",\"name\":\"Plasma Surface Treating - Enercon Industries Corporation\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.enerconind.com\\\/plasma-treating\\\/#organization\"},\"alternateName\":\"Enercon Industries Corporation\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.enerconind.com\\\/plasma-treating\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.enerconind.com\\\/plasma-treating\\\/#organization\",\"name\":\"Enercon Industries Corporation\",\"alternateName\":\"Enercon Industries Corporation\",\"url\":\"https:\\\/\\\/www.enerconind.com\\\/plasma-treating\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.enerconind.com\\\/plasma-treating\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/media.enerconind.com\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2023\\\/07\\\/02145715\\\/logo-e-solo.png\",\"contentUrl\":\"https:\\\/\\\/media.enerconind.com\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2023\\\/07\\\/02145715\\\/logo-e-solo.png\",\"width\":365,\"height\":365,\"caption\":\"Enercon Industries Corporation\"},\"image\":{\"@id\":\"https:\\\/\\\/www.enerconind.com\\\/plasma-treating\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Unique and Custom Plasma Treating Designs for Difficult to Reach\u00a0Surfaces - Plasma Surface Treating","description":"Learn about unique plasma surface treatment heads that are effective for hard to reach spaces.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.enerconind.com\/plasma-treating\/library-resource\/unique-and-custom-plasma-treating-designs-for-difficult-to-reach-surfaces\/","og_locale":"en_US","og_type":"article","og_title":"Unique and Custom Plasma Treating Designs for Difficult to Reach\u00a0Surfaces - Plasma Surface Treating","og_description":"Learn about unique plasma surface treatment heads that are effective for hard to reach spaces.","og_url":"https:\/\/www.enerconind.com\/plasma-treating\/library-resource\/unique-and-custom-plasma-treating-designs-for-difficult-to-reach-surfaces\/","og_site_name":"Plasma Surface Treating","article_modified_time":"2026-03-23T20:15:59+00:00","og_image":[{"width":384,"height":266,"url":"https:\/\/media.enerconind.com\/wp-content\/uploads\/sites\/4\/2023\/09\/02144950\/blown-ion-custom-vertical-and-quad-ports.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.enerconind.com\/plasma-treating\/library-resource\/unique-and-custom-plasma-treating-designs-for-difficult-to-reach-surfaces\/","url":"https:\/\/www.enerconind.com\/plasma-treating\/library-resource\/unique-and-custom-plasma-treating-designs-for-difficult-to-reach-surfaces\/","name":"Unique and Custom Plasma Treating Designs for Difficult to Reach\u00a0Surfaces - Plasma Surface Treating","isPartOf":{"@id":"https:\/\/www.enerconind.com\/plasma-treating\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.enerconind.com\/plasma-treating\/library-resource\/unique-and-custom-plasma-treating-designs-for-difficult-to-reach-surfaces\/#primaryimage"},"image":{"@id":"https:\/\/www.enerconind.com\/plasma-treating\/library-resource\/unique-and-custom-plasma-treating-designs-for-difficult-to-reach-surfaces\/#primaryimage"},"thumbnailUrl":"https:\/\/media.enerconind.com\/wp-content\/uploads\/sites\/4\/2023\/09\/02144950\/blown-ion-custom-vertical-and-quad-ports.jpg","datePublished":"2023-09-27T21:38:31+00:00","dateModified":"2026-03-23T20:15:59+00:00","description":"Learn about unique plasma surface treatment heads that are effective for hard to reach spaces.","breadcrumb":{"@id":"https:\/\/www.enerconind.com\/plasma-treating\/library-resource\/unique-and-custom-plasma-treating-designs-for-difficult-to-reach-surfaces\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.enerconind.com\/plasma-treating\/library-resource\/unique-and-custom-plasma-treating-designs-for-difficult-to-reach-surfaces\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.enerconind.com\/plasma-treating\/library-resource\/unique-and-custom-plasma-treating-designs-for-difficult-to-reach-surfaces\/#primaryimage","url":"https:\/\/media.enerconind.com\/wp-content\/uploads\/sites\/4\/2023\/09\/02144950\/blown-ion-custom-vertical-and-quad-ports.jpg","contentUrl":"https:\/\/media.enerconind.com\/wp-content\/uploads\/sites\/4\/2023\/09\/02144950\/blown-ion-custom-vertical-and-quad-ports.jpg","width":384,"height":266,"caption":"Custom plasma treating heads for hard-to-reach places."},{"@type":"BreadcrumbList","@id":"https:\/\/www.enerconind.com\/plasma-treating\/library-resource\/unique-and-custom-plasma-treating-designs-for-difficult-to-reach-surfaces\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.enerconind.com\/plasma-treating\/"},{"@type":"ListItem","position":2,"name":"Technical Article","item":"https:\/\/www.enerconind.com\/plasma-treating\/resource_type\/technical-article\/"},{"@type":"ListItem","position":3,"name":"Unique and Custom Plasma Treating Designs for Difficult to Reach\u00a0Surfaces"}]},{"@type":"WebSite","@id":"https:\/\/www.enerconind.com\/plasma-treating\/#website","url":"https:\/\/www.enerconind.com\/plasma-treating\/","name":"Plasma Surface Treating - Enercon Industries Corporation","description":"","publisher":{"@id":"https:\/\/www.enerconind.com\/plasma-treating\/#organization"},"alternateName":"Enercon Industries Corporation","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.enerconind.com\/plasma-treating\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.enerconind.com\/plasma-treating\/#organization","name":"Enercon Industries Corporation","alternateName":"Enercon Industries Corporation","url":"https:\/\/www.enerconind.com\/plasma-treating\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.enerconind.com\/plasma-treating\/#\/schema\/logo\/image\/","url":"https:\/\/media.enerconind.com\/wp-content\/uploads\/sites\/4\/2023\/07\/02145715\/logo-e-solo.png","contentUrl":"https:\/\/media.enerconind.com\/wp-content\/uploads\/sites\/4\/2023\/07\/02145715\/logo-e-solo.png","width":365,"height":365,"caption":"Enercon Industries Corporation"},"image":{"@id":"https:\/\/www.enerconind.com\/plasma-treating\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.enerconind.com\/plasma-treating\/wp-json\/wp\/v2\/resources\/1836","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.enerconind.com\/plasma-treating\/wp-json\/wp\/v2\/resources"}],"about":[{"href":"https:\/\/www.enerconind.com\/plasma-treating\/wp-json\/wp\/v2\/types\/resources"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.enerconind.com\/plasma-treating\/wp-json\/wp\/v2\/media\/1838"}],"wp:attachment":[{"href":"https:\/\/www.enerconind.com\/plasma-treating\/wp-json\/wp\/v2\/media?parent=1836"}],"wp:term":[{"taxonomy":"resource_type","embeddable":true,"href":"https:\/\/www.enerconind.com\/plasma-treating\/wp-json\/wp\/v2\/resource_type?post=1836"},{"taxonomy":"technology","embeddable":true,"href":"https:\/\/www.enerconind.com\/plasma-treating\/wp-json\/wp\/v2\/technology?post=1836"},{"taxonomy":"material","embeddable":true,"href":"https:\/\/www.enerconind.com\/plasma-treating\/wp-json\/wp\/v2\/material?post=1836"},{"taxonomy":"application_subcategory","embeddable":true,"href":"https:\/\/www.enerconind.com\/plasma-treating\/wp-json\/wp\/v2\/application_subcategory?post=1836"},{"taxonomy":"resource_application","embeddable":true,"href":"https:\/\/www.enerconind.com\/plasma-treating\/wp-json\/wp\/v2\/resource_application?post=1836"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}