Low Output Power

The following is a description of low output power on an Enercon Compak 9000 power supply.

Symptom

The output power is less than the desired setpoint level. Adjusting the power level in manual has no effect.

Fault

The power supply is in a limit condition.

Solution

  1. Check the front panel to determine if the power supply is in a limit condition.
  2. Current limit - The power supply is operating in a mismatched condition. Check the station air gap. Verify the gap is at .060".
  3. Contact Enercon's Service Department for further assistance.