Breaker Trip

The following is a description of a breaker trip on an Enercon Compak 9000 power supply. This condition may result from a variety of circumstances.

Symptom

With the circuit breaker energized and power available to the power supply, the micro display is blank and the cooling fans in the power supply do not energize.

Fault

The control power circuit in the power supply is defective.

Solution

  1. Inspect the cooling fans for a faulty fan. (Item 8)
  2. Check for a short circuit relating to the control transformer. (Item 21)
  3. Check the circuit breaker for defects.

Symptom

The breaker on the power supply trips when the interlocks for the system are satisfied but only after the start button is depressed.

Fault

The fault is most likely a short circuit in the AC-DC conversion section of the power supply. When the interlocks are satisfied, the contactor closed, allowing the charging of the DC bus. To isolate the fault perform the checks described on page 2.

Enercon Surface Treating Information Request

We appreciate your interest in Enercon corona, plasma, and flame surface treating solutions. Please complete the form below and we will process your request.

Company:
Name:
E-Mail:
Telephone:
Questions/Comments:




Enercon Surface Treating Information Request

We appreciate your interest in Enercon corona, plasma, and flame surface treating solutions. Please complete the form below and we will process your request.

Company:
Name:
E-Mail:
Telephone:
Questions/Comments: