Compak Power Supply Troubleshooting Sheet
|
|
- Checking for failed Bridge Rectifier, Chopper Device and Inverter Device
- Any "Zero" ohm reading will constitute a bad Semi-Conductor
- Meter Required: Standard Analog VOM OR DVOM with Diode Test.
| |
Meter Hook Up |
VOM (RX1 Scale) |
DVOM (Diode Test) |
| A to C |
(+)A/(-)C, (-)D&(+)E |
Open |
Open |
| A to D |
(-)A/(+)C, (+)D&(+)E |
~10 Ohms |
0.4V |
| then |
(+)B/(-)C, (-)D&(+)E |
~10 Ohms |
0.4V |
| A to E |
(-)B/(+)C, (+)D&(+)E |
Open |
Open |
 |
(+) Positive Meter Lead
(-) Negative Meter Lead |
| Meter Hook Up |
VOM (RX1 Scale) |
DVOM (Diode Test) |
| (+)A to (-)B |
Open |
Open |
| (-)A to (+)B |
~20 Ohms |
0.4V |
| (+)A to (-)C |
~20 Ohms |
0.4V |
| (-)A to (+)C |
Open |
Open |
| (+)B to (-)C |
~40 Ohms |
0.8V |
| (-)B to (+)C |
Open |
Open |
| (+)D to (-)E* |
Slight Deflection, Then Open |
Open |
| (+)G to (-)F* |
Slight Deflection, Then Open |
Open |
 |
(+) Positive Meter Lead
(-) Negative Meter Lead |
|
| *Use Highest Resistance Scale and Measure with Gate Leads Disconnected |
|
|
|