Chopper Fault

The following is a description of a blank micro display on an Enercon Compak 9000 power supply. This condition may result from a variety of circumstances, please note multiple symptoms & solutions exist on this page.

Chopper Fault
Symptom, Fault
Symptom The chopper fault light is illuminated when the power supply is started.
Fault The chopper device or control circuitry has failed.
CAUTION! When replacing the chopper device, always change the associated gate leads. If not, the lead may be defective and cause further device failures.
   
Solutions
  1. Check the chopper device in accordance with the device checks on page 2. (Item 14).
    1. If a defective device is identified, replace the device and gate leads and restart power supply.
    2. If no defective device is identified, replace the driver board (Item11)
  2. If problem persists, contact Enercon's Service Department for assistance.