Station Faults

The following is a description of station faults on an Enercon surface treating system.

Station Faults
Symptom, Fault
Symptom High rate of electrode failure. The electrodes are failing within a short time after they are installed.
Fault Electrode failure is caused by mechanical shock, or most likely insufficient air flow amounts required to cool the electrode.
   
Solutions
  1. Ensure the electrodes are not failing as a result of a physical contact from the web or a splice passing through the station.
  2. Verify the exhaust air passages in the electrode support tube are clear and free of obstruction.
  3. Measure the total air flow and the static pressure drop at the exhaust plenum for the station.
    1. The air flow should be about 100cfm per KW (i.e. 10KW=1000cfm).
    2. The exhaust plenum should have a static pressure of 10" w.c.