enercon industries Enercon Industries


1.262.255.6070 
enercon corona, plasma, flame surface treating systems      
Timer
About Us  |  Products  |  Support  |  Library  |  Resources  |  Contact Us  |  Home
  Support > Power Lok II
 
About Us
Products
Support
Application Support
Support FAQ
Maintenance Tips
Compak 2000
Compak 9000
Power Lok II
Breaker Trip
Fans do not energize with the breaker
Green light momentarily lights then goes out
No Output Power
Output Power Cycles
Unit Will Not Start
Treating Stations
Return Procedures
Warranty Registration
Training
Library
Resources
Contact Us
Home

Unit Will Not Start

The following is an outline of symptoms, faults, and solutions for your Enercon Power Lok II power supply.

Unit Will Not Start
Symptom & Fault
Symptom Unit will not start & green light will not illuminate
Fault Interlock open
   
Solution
  1. Place a jumper between 13 and 14 on the control wire terminal block to defeat the interlocks. If the green light comes on, troubleshoot the station interlocks. These include the electrode limit switches, airflow switches, zero speed switches, and purge interlock.
About Us | Products | Support | Library | Resources | Contact Us | Home

Copyright © 1996-. Enercon Industries Corporation.
All rights reserved. Do not duplicate or redistribute in any form.